Shoutout to the old timer in Tulsa who said skip the resistor and just home run it
Had a zone that kept tripping on a 20 year old panel out in Tulsa, and this old installer from the supply house said to quit messing with the end of line resistor and run a clean home run back to the can. Took his word and pulled 85 feet of new 22/4 through the attic, and the zone has been solid for 6 weeks with no faults. What is your go-to fix when a zone reads fine on the meter but trips every other day?