Spent 6 hours chasing a phantom zone fault on a 12-zone panel
Honestly, I wanted to throw my meter through a window yesterday. Had a 12-zone panel in Portland that kept showing a fault on zone 7, so I swapped the sensor first, then the wire run, then the resistor, nothing worked. Turns out the client had stapled a picture frame right through the wire in the hallway, and the staple was barely touching the conductor, so it only faulted when the house shifted. I found it after about 6 hours by wiggling every inch of that run with a tone generator, and the staple popped loose in my hand. Tbh I should have checked the run first instead of trusting the old sensor. Ngl, that one staple cost me a whole Saturday. Any of you got a trick for finding a partial short like that faster, or do you just eat the hours too?